MST Technology Website

North America

 

Semicondustor VMB Tool Gas Detector Monitor USA and Canada

MST Multi Gas Detector Technical Overview

 

 

Facility Requirements

 
Power requirements
  Voltage 230 VAC / 50 Hz
115 VAC / 60 Hz
  Consumption approx. 34 W
Alarm relays 250 VAC 1.5 A
30 VDC 3 A
LED indicators  
  Low alarm Yellow
  High alarm Red
Interface CAN high speed
506kbaud
Display 64 x 100 dots
Physical dimensions  
  Size 19.92 x 43.18 x 13.97 cm
5,875 x 17.0 x 5.50 inchs
  Weight approx. 5 kg
Sample line  
  Inlet 1/4 in OD
  Outlet 1/4 in OD
  Flow rate 0.8 lpm
Housing Protection IP 30
Operating conditions  
  Temperature 20° C to 40° C
68° F to 104° F
  Humidity 10 to 90% RH non-condensing

Cross Interference Table

 A indicates that the sensor (top) responds to the listed gas. The data is only valid for gas concentrations within the measuring range.
 Gas

Sensor

SiF4 HBr CO Cl2 NF3 C4F6
SiF4      
HBr    
CO          
Cl2  

Configuration Table

 A indicates the proper configuration for your target gas.
 MGD
Type

Desired Gas

SiF4 HBr CO Cl2 NF3 C4F6
Type 110      
Type 120/150    
Type 130/160        
Type 140          
 
 
Product Information  
   
 
 

Multi Gas Detector

bullet Multi Gas Detector
bullet Detectable Gases
bullet Technical Overview
bullet Quick Facts
bullet Configuration Table
bullet Cross Interference Table
Printable Data
bullet Brochure
Application Notes
bullet In-Situ vs. Extractive
Models Number
bullet 20304-0100 MGD
Contact a sales professional
Buy online
 
 

Semicondustor VMB Tool Gas Detector Monitor USA and Canada

Store Contact    Impressum    Add to favorites     Site Suggestions   Recommend Us    Privacy Statement
MST Technology - International Sites:  Global
   Europe   North America    Asia
Honeywell International
    Honeywell Analytics

© MST Technology, Inc. 2005-2008 - All rights reserved